Measurement key figures

Useful levels

At the wall outlet / antenna socket according to EN 60728-1 in dBµV

Transmission standard Modulation Min. Max.
FM (mono/stereo) FM 40/50 70
PAL AM residual band 60 77
DVB-C 16 QAM 41 61
DVB-C / DOCSIS downstream 64 QAM 47 67
DVB-C / DOCSIS downstream 256 QAM 54 74
DVB-S/S2 QPSK, 8 PSK, 16 APSK, 32 APSK 47 77
DVB-T COFDM; 16 QAM; FEC = 2/3 36 74
DVB-T COFDM; 64 QAM; FEC = 2/3 45 74
DVB-T2 COFDM; 16 QAM; FEC = 2/3 35 74
DVB-T2 COFDM; 64 QAM; FEC = 2/3 39 74
DAB und DAB+ COFDM in band III 28 94