SZU 6-01 Surge protection device | IEC-male | IEC-female

  • For terrestrial, CATV and satellite TV networks

  • Complies with EN 61643-21



Bild CE.png Bild KlasseA.png Bild WideBand.png Bild AND.png Bild HFC.png

Type SZU 6-01
Order no. SZU00601
GTIN 7611682160611
PE 1
VE 1
EU custom tariff number 85291080
Screening factor acc. to EN 50083-2 Class A
Frequency range 5…2400 MHz
Through loss 0.8 dB @ 5…1000 MHz
1.2 dB @ 1000…2400 MHz
Max. through current 0.5 A @ 30 VDC
DC breakdown voltage 230 ± 42 V @ 100 V/s
Impulse spark-over voltage ≤ 800 V @ 1 KV/μs
Alternating discharge current 5 A @ 50Hz/1s
Impulse discharge current 5 KA @ 8/20 μs
Impedance 75 Ω
Connectors
Connector type IEC-male (input) | IEC-female (output)
Return loss 12 dB
General
Dimensions (W × H) Ø 13 x 58 mm
Weight 0.019 kg

Ask a question

Your email address will not be published. Required fields are marked *


  1. herbert:

    wie erkenne ich, dass Schutzfunktion aktiv/inaktiv ist ?

    • AXING:

      Es gibt keine Möglichkeit, den Schutz auszuschalten. Die Schutzfunktion ist also immer aktiv, auch wieder nachdem sie ausgelöst hat.