MIM 816-02N Extension module for MIE 816-02N

  • Extension to additional 512 input streams and additional 8 DVB-T2 output channels



Bild CE.png Bild DVB-IPTV.png Bild DVB-T2.png Bild HD.png Bild AND.png Bild HFC.png

Type MIM 816-02N
Order no. MIM81602N
GTIN 7611682400137
PE 1
VE 1
EU custom tariff number 85176990
IPTV input
Max. number (out of SPTS or MPTS) 512
Total net data rate 1 × 900 Mbps
Transportstreams
Modifiable program information Program name, SID remapping, PID filtering, TSID, ONID
PCR correction automatic, adaptive, < 500 ns
LCN Yes
EPG regeneration Yes
Encryption DVB-CSA* | DVB-CISSA* | ATIS-IDSA* | AES-ECB* | AES-CBC*
Output
Number of channels 1 × 8 × DVB-T2
Frequency range 114 … 1006 MHz
Channels selectable D114 … D1002
Channel bandwidth 7/8 MHz
Possible frequency shift −4 … +4 MHz (0.5 MHz steps)
Connector 1 × F-female
Test port 1 × F-female (–30 dB)
Impedance 75 Ω
Output level adjustable 89 … 105 dBµV
Output modulation
Compliance DVB-T2 (EN 302 755, mode A (single PLP))
EN 50083-9 | ETSI TS 101 154 | ETSI EN 300 429 | ETSI EN 300 744
L1 post signalling BPSK, QPSK, 16-QAM, 64-QAM
Type QPSK, 16-QAM, 64-QAM, 256-QAM
Supported output formats MPEG-2/H.262, MPEG-4/H.264 and HEVC/H.265
MER > 43 dB
BER < 9 x 10-9
Shoulder attenuation > 56 dB
C/N > 45 dB
Reflection < −14 dB
Bit rate, max 50.35 Mbps
FFT 1k, 2k, 4k, 8k, 16k mode (ext)
FEC type BCH, LDPC
FEC length 16200, 64800
FEC 1/2, 3/5, 2/3, 3/4, 4/5, 5/6
Pilot pattern PP1 … PP12
Guard interval 1/4, 1/8, 1/16, 1/32
Interfaces
Ethernet connectors (LAN) 4 x RJ45
Ethernet standards IEEE 802.3, 100 Base-T @ Control
IEEE 802.3, 1000 Base-T /1 GbE @ IPTV IN1, IPTV IN2, CAS
Software control and upgrading Via Remote Access
Supported configuration protocols HTTP, SNMP v1, SNMP v2c, AXING SMARTPortal**
General
Operating temperature range (acc. to EN 60065) –10 °C … +50 °C
Storage temperature range (acc. to EN 60065) –20 °C … +80 °C
Weight 0.516 kg
Comments * with software extension MIS 1-11 only
** * with software extension MKS 1-02 only