BSD 963-14N Multimedia loop-through outlet 14 dB | 5…1006 MHz | CATV | DATA

  • Class A (+10 dB) according to EN 50083-2

  • Suitable for broadband return path

  • Easy to install

  • Stripping length 8/13 mm

  • Extended F socket

  • Surface treaded

  • Vodafone listed



Bild CE.png Bild KlasseA+10.png Bild VodafoneGelistet.png Bild 4Gprotected.png Bild UltraHD.png Bild AND.png Bild HFC.png

Type BSD 963-14N
Order no. BSD96314N
GTIN 7611682001549
PE 1
VE 1
EU custom tariff number 85291095
Screening factor acc. to EN 50083-2 Class A (+ 10 dB)
Trunk line
Frequency range input 5…1006 MHz
Through loss @ 5…1006 MHz ≤ 2.5 dB
Frequency range output 5…1006 MHz
Suitable cables (Inner conductor | outer diameter) 0.63…1.13 mm | 4.70…7.35 mm
TV connector
Connector type IEC-male
Frequency range 109...1006 MHz
Tap loss 14 dB ±1 dB
Radio connector
Connector type IEC-female
Frequency range 87.5…125 MHz
Tap loss 16 dB ±1.5 dB
DATA connector
Connector type F-female
Frequency range 5…1006 MHz
Tap loss 14 dB ±1 dB
Isolation TV↔DATA @ 5…65 MHz ≥ 70 dB
Isolation TV↔DATA @ 109…1006 MHz ≥ 30 dB
General
Dimensions (W × H × D) appr. 68 × 68 × 39 mm
Weight 0.100 kg

Ask a question

Your email address will not be published. Required fields are marked *


  1. Dag Eismann:

    Guten Morgen ans Axing Team, bis wieviel Mhz im Rückkanal ist die BSD 963-14N Dose R tauglich

    • AXING:

      Es gibt keine Grenze oder Filterung für den Rückkanal. Bei der Entwicklung der Dose wurden bisher übliche Rückkanalfrequenzen bis 204 MHz berücksichtigt, aber auch höhere wären möglich.