2 SAT positions with quattro LNB
-
4 SAT positions with wideband LNBs (EN 50607 only)
-
2 out of 4 SAT positions with wideband LNBs (EN 50494)
-
With terrestrial feed-in
-
Suitable for broadband return path (EoC suitable up to 204 MHz)
-
Cascadable
-
8 outputs with 4 user bands each
-
Single cable I and II compatible (according to EN 50607 and EN 50494)
-
Interference-free, no interference across flats when using programmable SSD 6-xx antenna wall outlets
-
Alternatively up to 8 legacy outputs (not with wideband LNBs or SSD 6-xx)
-
Ext. power supply SZU 99-06 needed (not included in delivery)
Type | SES 984-06 |
---|---|
Order no. | SES98406 |
GTIN | 7611682006100 |
PE | 1 |
VE | 1 |
EU custom tariff number | 85291095 |
Inputs | |
---|---|
Number | 9 |
Frequency range |
5…862 MHz @ TERR 250…2350 MHz @ SAT |
LNB voltage | 12 V |
Max. LNB current |
500 mA per LNB 1000 mA total |
Level | 60… 90 dBµV |
Isolation V | H | 30 dB |
Subscriber ports | |
Number | 8 |
Supported standards | EN 50494, EN 50607 |
Tap loss TERR | 22 dB |
Frequency range (SAT) | 950…2150 MHz |
User bands | 8 × 4 |
User band frequencies | 1331/1382/1433/1484 MHz |
Output level SAT (SCR/CSS) | 83/82 dBμV* |
Output level SAT (Legacy) | 83/82 dBμV* |
Current consumption from STB (SCR/CSS) | 180 mA |
Current consumption from STB (Legacy) | 60 mA |
Trunk outputs | |
Number | 9 |
Through loss TERR | 2 dB ±2.0 dB |
Through loss SAT | 5 dB ±2.0 dB |
Connectors | |
Connector type | F |
Return loss | ≥ 10 dB |
General | |
Equipotential bonding connection | 4 mm² |
Operating temperature range (acc. to EN 60065) | -20…70°C |
Dimensions (W × H × D) appr. | 205 x 310 x 63 mm |
Weight | 1.05 kg |
Comments | *AGC |
Data sheet | Data sheet SES 984-06.pdf |
---|---|
Operational instructions |
BA_SES-984-06.pdf
|
EU declaration of conformity |
CE/AXING-CE_SES-984-06.pdf
|
Other documents |
AXING-INFO_SAT_EN.pdf
AXING-Flyer_QEW_EN.pdf |
5 Mai, 2021 um 10:54 Uhr
Hallo Axing-Team
Ich habe eine Frage zum SES 984-06,
mit welchem Sat-Ausgangspegel läuft dieser Einkabel-Multischalter im Legacy Betrieb?
mfg Lutz Trier
5 Mai, 2021 um 18:31 Uhr
Der Pegel im Legacy-Modus wird auch von der AGC geregelt. Bei einem Eingangspegel von 75 bis 85 dBµV ist der Ausgangspegel ca. 82 dBµV. Bei einem geringeren Eingangspegel reduziert sich der Ausgang entsprechend. Bei 70 dBµV Eingangspegel kommen im Legacy-Modus ca. 77 dBµV heraus.