BAB 1-06X 1-way tap | 6 dB | 5 … 1800 MHz | housing design 01

  • Suitable for DOCSIS 3.1 and 4.0

  • Class A (+10 dB) according to EN 50083-2

  • Inputs and outputs hum-suppressed

  • High intermodulation suppression

  • High return loss and isolation



Bild CE.png Bild KlasseA+10.png Bild UltraHD.png Bild AND.png Bild HFC.png

Type BAB 1-06X
Order no. BAB00106X
GTIN 7611682009224
PE 1
VE 1
EU custom tariff number 85291080
Frequency range 5 … 1800 MHz
Screening factor acc. to EN 50083-2 Class A + 10 dB
Surge Protection 1 kV @ 1.2/50 μs surge voltage according to IEC 61000-4-5 / 160 Vdc impulse and UM TS 41
Intermodulation ratio (EN 60728-4) < −115 dBc @ 120 dBµV
Taps 1-fach
Tap loss 7.0 ±0.2 dB @ 10 MHz
5.9 ±0.2 dB @ 65 MHz
5.8 ±0.2 dB @ 108 MHz
5.7 ±0.2 dB @ 204 MHz
5.7 ±0.2 dB @ 258 MHz
5.7 ±0.2 dB @ 470 MHz
5.8 ±0.3 dB @ 862 MHz
6.1 ±0.3 dB @ 1218 MHz
6.2 ±0.5 dB @ 1794 MHz
Through loss 2.3 ±0.3 dB @ 10 MHz
2.3 ±0.3 dB @ 65 MHz
2.3 ±0.3 dB @ 108 MHz
2.3 ±0.3 dB @ 204 MHz
2.5 ±0.2 dB @ 258 MHz
2.6 ±0.2 dB @ 470 MHz
2.7 ±0.3 dB @ 862 MHz
2.8 ±0.3 dB @ 1218 MHz
3.5 ±0.4 dB @ 1794 MHz
RF connectors
Type F-Buchse (IEC 61169-24)
Isolation
Tap-Out > 33 dB @ 10 … 204 MHz
> 28 dB @ 204 … 862 MHz
> 25 dB @ 862 … 1218 MHz
> 22 dB @ 1218 … 1794 MHz
Connectors
Connector type F female (IEC 61169-24)
Impedance 75 Ohm
Return loss > 20 dB @ 10 … 204 MHz
> 19 dB @ 204 … 862 MHz
> 17 dB @ 862 … 1218 MHz
> 15 dB @ 1218 … 1794 MHz
General
Operating temperature range −15 °C … +60 °C
Dimensions (W × H × D) appr. 45 × 55 × 25 mm
IP code IP67