Class A (+10 dB) according to EN 50083-2
-
Suitable for return path 5…65 MHz
-
Suitable for Unicable I (EN50494) and Unicable II (EN50607)
-
Isolated with diodes
-
Easy to install
-
Stripping length 8/13 mm
-
Extended F socket
-
Surface treaded
Type | SSD 5-10 |
---|---|
Order no. | SSD00510 |
GTIN | 7611682000900 |
PE | 1 |
VE | 1 |
EU custom tariff number | 85291095 |
Screening factor acc. to EN 50083-2 | Class A (+ 10 dB) |
---|---|
Tap method | Filter circuit/directional coupler |
Trunk line | |
Frequency range input | 5…2200 MHz |
Through loss |
≤ 2.0 dB @ 5…862 MHz ≤ 3.0 dB @ 862…2200 MHz |
Frequency range output | 5…2200 MHz |
DC power pass | yes |
Suitable cables (Inner conductor | outer diameter) | 0.63…1.13 mm | 4.70…7.35 mm |
TV connector | |
Connector type | IEC-male |
Frequency range | 109…862 MHz / 5…65 MHz |
Tap loss | 10 dB ±1.5 dB |
Radio connector | |
Connector type | IEC-female |
Frequency range | 87.5…125 MHz |
Tap loss | 13 dB ±2.0 dB |
SAT connector | |
Connector type | F female |
Frequency range | 950…2200 MHz |
Tap loss | 10 dB ±1.5 dB |
DC power pass to trunk | yes |
General | |
Dimensions (W × H × D) appr. | 68 × 68 × 39 mm |
Weight | 0.104 kg |
Data sheet | Data sheet SSD 5-10.pdf |
---|---|
Operational instructions |
AXING-BA_BSD-SSD.pdf
|
Other documents |
AXING-INFO_Zubehoer_EN.pdf
|
9 Oktober, 2022 um 08:41 Uhr
Kann die Durchgangsdose SSD 5-10 auch als Enddose mit DC entkoppeltem 75 Ohm Abschlußwiderstand (anstelle Kabelabgang) verwendet werden? Grund: später soll die Stchleitung zu einer Stammleitung mit mehreren Dosen erweitert werden.
Besten Dank, Walter Neumann
10 Oktober, 2022 um 10:30 Uhr
Ja, die SSD 5-10 kann so betrieben werden. Wichtig ist, dass der Abschlusswiderstand DC-entkoppelt ist, z.B. TZU 3-01.