For up to 12 subscribers
-
SAT active, CATV path active switchable and adjustable
-
Suitable for broadband return channel with passive CATV path (suitable for EoC up to 204 MHz)
-
With passive CATV path and Quattro LNB receiver-powered - no power supply unit required
-
With active CATV path or Quad LNB, power supply via external power supply unit SZU 99-09S (not included) or via the SAT IF trunk lines
-
Advanced standby and energy saving functionalities (e.g. only the required LNB is powered)
-
USB-C port for external power supply unit
-
Cascadable (unused cascade outputs must be terminated with DC-decoupled 75 Ohm terminating resistors (e.g. CFA 11-00, not included in the scope of delivery))
| Type | SPU 912-09S |
|---|---|
| Order no. | SPU91209S |
| GTIN | 7611682400717 |
| PE | 1 |
| VE | 1 |
| EU custom tariff number | 85291095 |
| Inputs | |
|---|---|
| Number | 9 |
| Frequency range | 5 … 862 MHz | 950 … 2200 MHz |
| Max. LNB current | 2000 mA |
| Attenuator CATV adjustment range, switchable to passive | 0 … 20 dB |
| Isolation V | H | 30 dB |
| Isolation CATV | SAT | 30 dB |
| Subscriber ports | |
| Number | 12 |
| Switch commands | 13V,18V,13V/22kHz,18V/22kHz, DiSEqC 2.0 |
| Tap loss CATV active | 0 dB |
| Tap loss CATV passive | 28 dB |
| Max. output level SAT (3rd order SAT EN 50083‑3 35dB KMA, 2 sender test method) | 100 dBµV |
| Max. output level CATV (3rd order, EN 50083‑3, 60 dB KMA) | 90 dBuV |
| Current consumption per port (without LNB supply) | 50 mA |
| Trunk outputs | |
| Number | 9 |
| Max. output level CATV (3rd order EN 50083‑3, 60 dB KMA) | 103 dBuV |
| Through loss CATV active | –23 dB |
| Through loss CATV passive | 7 dB |
| Through loss SAT | 3 dB |
| Connectors | |
| Connector type | F-female |
| General | |
| Operating temperature range (acc. to EN 60065) | –20 … +55° C |
| Operating voltage | 15 … 20 VDC* |
| Equipotential bonding connection | 4 mm² |
| Dimensions (W × H × D) appr. | 178 x 230 x 65 mm |
| Weight | 0.760 kg |
| IP code | IP20 |
| Comments | *USB-C power supply units must fulfil the Power Delivery (PD) standard and have an output voltage of 20 VDC |
| Data sheet | Data sheet SPU 912-09S.pdf |
|---|