For SAT or CATV indoor installation
-
Class A+ according to EN 50117-2-4
-
Fire behaviour Eca acc. to EN 50575
-
Inner conductor StCu, diameter 1.02 mm
-
Physically-foamed dielectric, diameter 4.6 mm
-
Screening aluminium foil, bonded/aluminium braiding/aluminium foil
-
Jacket PE, black
-
UV resistent
-
Degressive metering
-
250 m in a opti-box
| Type | SKB 395-14 |
|---|---|
| Order no. | SKB39514 |
| GTIN | 7611682002539 |
| PE | 1 |
| VE | 2 |
| EU custom tariff number | 85442000 |
| Electrical data | |
|---|---|
| Impedance | 75 Ω |
| Attenuation |
8.7 dB / 100 m @ 200 MHz 18.0 dB / 100 m @ 800 MHz 32.9 dB / 100 m @ 2400 MHz |
| Screening factor |
>100 dB @ 30…1000 MHz >100 dB @ 1000…2000 MHz >100 dB @ 2000…3000 MHz |
| Coupling resistance | <2.5mOhm/m |
| Mechanical data | |
| Inner conductor material | diameter | StCu | 1.02 mm |
| Dielectric diameter | 4.6 mm |
| Braiding | opt. coverage | 80 x 0.12 mm | 55% |
| Jacket material | diameter | PE | 6.8 mm |
| Bending radius single | multiple | 24 mm | 68 mm |
| General | |
| Application temperature range | –5…+50°C |
| Operating temperature range | –20…+75°C |
| Fire behaviour | Eca |
| Weight | 8.360 kg |
| Data sheet | Data sheet SKB 395-14.pdf |
|---|---|
| EU declaration of conformity |
CE/AXING-CE_SKB-395-14.pdf
CE/AXING-DoP-030_SKB-395-14.pdf CE/AXING-CE-Label-030_SKB-395-14.pdf |


Ask a question