For SAT or CATV indoor installation
-
Class A+ according to EN 50117-2-4
-
Fire behaviour Eca acc. to EN 50575
-
Inner conductor StCu, diameter 1.02 mm
-
Physically-foamed dielectric, diameter 4.6 mm
-
Screening aluminium foil, bonded/aluminium braiding/aluminium foil
-
Jacket PVC, white
-
UV resistent
-
Degressive metering
-
100 m on a cardboard spool
Type | SKB 395-01 |
---|---|
Order no. | SKB39501 |
GTIN | 7611682113952 |
PE | 1 |
VE | 4 |
EU custom tariff number | 85442000 |
Electrical data | |
---|---|
Impedance | 75 Ω |
Attenuation |
8.7 dB / 100 m @ 200 MHz 18.0 dB / 100 m @ 800 MHz 32.9 dB / 100 m @ 2400 MHz |
Screening factor |
>100 dB @ 30…1000 MHz >100 dB @ 1000…2000 MHz >100 dB @ 2000…3000 MHz |
Coupling resistance | <2.5mOhm/m |
Mechanical data | |
Inner conductor material | diameter | StCu | 1.02 mm |
Dielectric diameter | 4.6 m |
Braiding | opt. coverage | 80 x 0.12 mm | 55% |
Jacket material | diameter | PVC | 6.8 mm |
Bending radius single | multiple | 24 mm | 68 mm |
General | |
Application temperature range | –5…+50°C |
Operating temperature range | –20…+75°C |
Fire behaviour | Eca |
Weight | 3.805 kg |
30 November, 2022 um 09:18 Uhr
Darf SKB 395-01 ungeschützt vor UV-Strahlung im Außenbereich verlegt werden
30 November, 2022 um 10:19 Uhr
Wir empfehlen für den Außenbereich die UV-beständige Version SKB 395-11 zu verwenden. Praktisch ist es, wenn Sie dieses Kabel zwischen LNB und Erdungswinkel verwenden. Vom Erdungswinkel zu dem Multischalter oder Teilnehmern kann dann wieder das weiße Kabel eingesetzt werden.