-  For SAT or CATV indoor installation 
-  Class A+ according to EN 50117-2-4 
-  Fire behaviour Eca acc. to EN 50575 
-  Inner conductor Cu, diameter 1.02 mm 
-  Physically-foamed dielectric, diameter 4.6 mm 
-  Screening aluminium foil, bonded/tinned copper braiding/aluminium foil 
-  Jacket PE LSZH, black 
-  UV resistent acc. UL1581 
-  Degressive metering 
-  100 m on a cardboard spool 
 
	 
	 
	 
	 
	 
| Type | SKB 94-11 | 
|---|---|
| Order no. | SKB09411 | 
| GTIN | 7611682400779 | 
| PE | 1 | 
| VE | 4 | 
| EU custom tariff number | 85442000 | 
| Electrical data | |
|---|---|
| Impedance | 75 Ω | 
| Attenuation | 9.5 dB / 100 m @ 200 MHz 19.5 dB / 100 m @ 800 MHz 35.0 dB / 100 m @ 2400 MHz | 
| Screening factor | ≥110 dB @ 30…1000 MHz ≥110 dB @ 1000…2000 MHz ≥110 dB @ 2000…3000 MHz | 
| Coupling resistance | <1.5 mOhm/m | 
| Mechanical data | |
| Inner conductor material | diameter | Cu | 1.02 mm | 
| Dielectric diameter | 4.57 mm | 
| Dielectric diameter, incl. bonded foil | 4.78 mm | 
| Braiding | opt. coverage | 120 x 0.1 mm | 60% | 
| Jacket material | diameter | PE LSZH | 6.60 mm | 
| Bending radius single | multiple | 24 mm | 69 mm | 
| General | |
| Application temperature range | –5…+50°C | 
| Operating temperature range | –40…+75°C | 
| Fire behaviour | Eca | 
| Weight | 4.500 kg | 
| Data sheet | Data sheet SKB 94-11.pdf | 
|---|---|
| EU declaration of conformity | CE/AXING-CE_SKB-94-11.pdf CE/AXING-DoP-057_SKB-94-11.pdf CE/AXING-CE-Label-057_SKB-94-11.pdf | 
 
  
 
 
		