For SAT or CATV indoor installation
-
Fire behaviour Eca acc. to EN 50575
-
Inner conductor StCu, diameter 1.02 mm
-
Physically-foamed dielectric, diameter 4.7 mm
-
Screening aluminium foil/aluminium braiding
-
Jacket PVC, white
-
Degressive metering
-
500 m on wooden drum
Type | SKB 88-03 |
---|---|
Order no. | SKB08803 |
GTIN | 7611682000061 |
PE | 1 |
VE | 1 |
EU custom tariff number | 85442000 |
Electrical data | |
---|---|
Impedance | 75 Ω |
Attenuation |
8.4 dB / 100 m @ 200 MHz 17.8 dB / 100 m @ 800 MHz 32.1 dB / 100 m @ 2400 MHz |
Screening factor |
> 85 dB @ 30…1000 MHz > 80 dB @ 1000…2000 MHz > 80 dB @ 2000…3000 MHz |
Coupling resistance | <16mOhm/m |
Mechanical data | |
Inner conductor material | diameter | StCu | 1.02 mm |
Dielectric diameter | 4.7 mm |
Braiding | opt. coverage | 64 x 0.12 mm | 45% |
Jacket material | diameter | PVC | 6.8 mm |
Bending radius single | multiple | 24 mm | 68 mm |
General | |
Application temperature range | –5…+50°C |
Operating temperature range | –20…+75°C |
Fire behaviour | Eca |
Weight | 19.340 kg |
Data sheet | Data sheet SKB 88-03.pdf |
---|---|
EU declaration of conformity |
CE/AXING-CE_SKB-88-03.pdf
CE/AXING-DoP-033_SKB-88-03.pdf CE/AXING-CE-Label-033_SKB-88-03.pdf |
Ask a question