5-way
-
Earthing and equipotential bonding acc. to EN 60728-11
-
For AXING multiswitches SPU 5xx-09 and headamplifiers SVS 5xx-09 at input
-
Incl. surge protection devices SZU 6-02
-
With premium-line double F-sockets CFA 26-02 and quickfix adapter CFA 4-01
| Type | QEW 5-10 |
|---|---|
| Order no. | QEW00510 |
| GTIN | 4026423971778 |
| PE | 1 |
| VE | 1 |
| EU custom tariff number | 85366910 |
| Application | SPU 5xx-09 / SVS 5x-09 |
|---|---|
| Frequency range | 5…2500 MHz |
| Screening factor acc. to EN 50083-2 | > 90 dB |
| DC power pass | yes |
| Through loss | ≤ 0.5 dB |
| Max. through current | 0.5 A @ 30 VDC |
| Impulse discharge current | 5 KA @ 8/20 μs |
| Connectors | |
| Connector type | F |
| Number | 5 |
| Return loss | 20 dB -1.5dB/Okt. |
| General | |
| Material | surface treated |
| Dimensions (W × H × D) appr. | 141 × 40 × 85 mm |
| Weight | 0.314 kg |
| Data sheet | Data sheet QEW 5-10.pdf |
|---|---|
| Other documents |
AXING-Flyer_QEW_EN.pdf
|


3 April, 2024 um 21:22 Uhr
Hallo,
wie wird die Erdungsleitung angeschlossen und in welchem Querschnittsberich ist dies möglich?
5 April, 2024 um 08:49 Uhr
Der Erdungsdraht wird an der vorgesehenen Schraube angeklemmt. Beim QEW 5-10 stehen dazu 2 Anschlüsse zur Verfügung. Der maximale Querschnitt beträgt 19 mm².