Easy start thanks to DVB-T2 and SAT wizard, intuitive operation
-
Ideal for use by installers, electricians and on the construction site
-
7-inch high-resolution touch display (800 × 480 px)
-
Including display of the TV picture by MPEG4 decoder (H.264)
-
Very good legibility even in poor lighting conditions
-
Measuring ranges DVB-T/-T2/-T2 Lite, DVB-C/-C2 and DVB-S/-S2 (incl. UNICABLE I and II as well as Wideband)
-
Extendable to DVB-S2X with software extension MGS 1-00
-
Frequency range SAT 200 … 2400 MHz (Wideband)
-
Frequency range DVB-T/T2/CATV 5 … 1005 MHz
-
Import of an individual frequency plan possible
-
Level measuring range 20 … 120 dBµV
-
Measurements: level (also analogue), BER, MER, packet error (PER), link margin, constellation diagram
-
Including spectrum analyser with full-band display or stepwise adjustment of the span
-
DiSEqC Version 1.2
-
Supply voltages 13/18 V for SAT, 5/13/18/24 V for DVB-T2 and CATV
-
Network interface RJ45 (10/100baseT), USB
-
Compact design, stable housing with robust bumpers
-
Built-in lithium-ion battery with 94 Wh for up to 5 hours operating time (depending on the use and a remote power supply for LNB or antenna)
-
Incl. F/F-adapter, charging unit, USB flash drive and carrying bag MGZ 1-00
-
User-friendly generation of measurement protocols thanks to the AXING-MCombiner software tool included in delivery
Type | MG 1-00 |
---|---|
Order no. | MG00100 |
GTIN | 7611682007916 |
PE | 1 |
VE | 1 |
EU custom tariff number | 85043180 |
Input | |
---|---|
Frequency range |
5 … 1005 MHz @ CATV / TERR 200 … 2400 MHz @ SAT |
LNB-Type | C | Ku | Ku WIDEBAND (LO adjustable) |
Level measurement | |
Range | 20 … 120 dBµV |
Units | dBµV | dBmV | dBm |
Accuracy | ± 2 dB ± 0.05 dB/°C |
Resolution | 0.1 dB |
Standards |
DVB-T/T2/T2Lite | DVB-C/C2 | BG | DK | I | L | MN | DAB | FM carrier @ CATV / TERR DVB-S/S2/S2X* | PAL | SECAM | NTSC carrier @ SAT |
Digital measurements | |
Packet errors and link margin (LKM) | Yes |
Modulation Error Rate (MER) |
15 … 35 dB @ DVB-T 15 … 35 dB @ DVB-T2/T2lite 20 … 40 dB @ DVB-C (J83.A) 25 … 35 dB @ DVB-C2 0 … 20 dB @ DVB-S 0 … 20 dB @ DVB-S2 0 … 20 dB @ DVB-S2X* |
Sensitivity |
35 dBµV @ DVB-T 35 dBµV @ DVB-T2/T2lite < 55 dBµV @ DVB-C (J83.A) < 55 dBµV @ DVB-C2 47 dBµV @ DVB-S 47 dBµV @ DVB-S2 47 dBµV @ DVB-S2X* |
Bandwidth |
6 | 7 | 8 MHz @ DVB-T 1.7 | 5 | 6 | 7 | 8 MHz @ DVB-T2/T2lite 6 | 8 MHz @ DVB-C2 |
Mode | PLP and data slice, simple or multiple @ DVB-C2 |
FFT |
2k | 8k @ DVB-T 1k | 2k | 4k | 8k | 16k | 32k + Band Extension @ DVB-T2/T2lite |
Modulation type |
QPSK, 16 - 64QAM @ DVB-T QPSK, 16 - 256QAM @ DVB-T2/T2lite 16, 32, 64, 128, 256QAM @ DVB-C (J83.A) 16, 64, 256, 1024, 4096QAM @ DVB-C2 QPSK @ DVB-S QPSK, 8PSK, 16, 32APSK @ DVB-S2 QPSK, 8PSK, 8, 16, 32APSK-L @ DVB-S2X* |
Symbol rate |
1 … 7.224 MS/s @ DVB-C (J83.A) 1 … 50 MS/s @ DVB-S 1 … 50 MS/s @ DVB-S2 1 … 50 MS/s @ DVB-S2X* |
HP/LP – PLP – Data Slice |
HP/LP @ DVB-T PLP @ DVB-T2/T2lite PLP + Data Slice @ DVB-C2 |
Multistream |
Stream selection 0 … 255 (ISI) PLS descrambling (Gold code) @ DVB-S2 Stream selection 0 … 255 (ISI) PLS descrambling (Gold code) @ DVB-S2X* |
Spectrum analysis | |
Span | 1 MHz to full span in 1, 2, 5 steps |
Sweep | 100 … 1000 ms |
Filters | 1.6 kHz | 3.2 kHz | 8 kHz | 16 kHz | 32 kHz | 80 kHz | 160 kHz | 320 kHz | 800 kHz | 1.6 MHz | 3.2 MHz |
Attenuation | 0 … 55 dB, in 5 dB steps (automatic) |
Display range / dynamic | 60 dB (10 dB/div) |
Remote supply/control | |
Supply |
5/13/18/24 V | 500 mA max. (300 mA @ 24V) @ DVB-T/T2 13 / 18V | 500 mA max. @ DVB-S/S2 |
DiSEqC | DiSEqC 2.1 | Dish Rotor Control | committed & uncommitted Switches |
DCSS |
Max. 8 user bands @ EN 50494 (UNICABLE I) Max. 32 user bands @ EN 50607 (UNICABLE II) |
Audio/Video | |
Audiocodecs | MPEG-1 | MPEG-2 | AAC | HE AAC | Dolby® Digital | Dolby® Digital Plus |
Videocodecs | MPEG-2 SD und MPEG-4 HD (H.264) |
Service tables | SDT | LCN |
Antenna check mode | |
Memory |
10 places/stations @ DVB-T/T2 30 satellites, with European database loaded @ DVB-S/S2 |
Check |
4** channels @ DVB-T/T2 4** transponders @ DVB-S/S2 |
Interfaces | |
Ethernet connectors (LAN) | 1 × RJ 45 |
Ethernet standards | IEEE 802.3 10/100 Base-T |
USB | USB-A / V1.1 (Full Speed) |
Connectors | |
RF Input | F-male (F-female/-F-female adaptor mounted) | 75 Ohms |
Max. permitted voltage | 50 VDC, 33 Veff / 50 Hz |
Analogue video input | Jack 3.5 mm | 4 contacts |
Level | Video 1 Vpp max. / Audio 10 kOhm |
Standards | PAL | SECAM | NTSC |
Power supply | Jack 5.5 mm (max 1 A) |
General | |
Display | Color LCD TFT | 7 inches | 16:9 | backlight (500 cd/m2) | resolution 800 x 480 | capacitive touch screen |
Operating voltage | 15 VDC |
Battery | Lithium Ion with 94 Wh (non-removable)*** |
Charging time | 6:45 h:min 80% | 9:30 h:min 100% |
Operating time | CATV/TERR: 5 h | SAT: 3 h (depending on use case) |
Operating temperature range | -5 … +40 °C |
Storage temperature range | -10 … +60 °C |
EMC and safety | NF-EN 61326-1 | NF-EN 61326-2 | NF-EN 61010-1 |
Dimensions (W × H × D) appr. | 280 x 300 x 70 mm |
Weight | 1.350 kg |
External accessories | |
Plug-in power supply | 110/230 VAC | 15 VDC / 1 A |
General | |
Comments |
* DVB-S2X only with software extension MGS 1-00 ** Can be changed by the user *** From serial number #6000 upwards |
Data sheet | Data sheet MG 1-00.pdf |
---|---|
Operational instructions |
AXING-BA_MG-1-00.pdf
AXING-QA_MG-1-00.pdf AXING-BA_MG-1-00_Softwareupdate.pdf |
Current software |
MG00100_V2_4.zip
|
Other documents |
AXING-Flyer_MG-1-00_EN.pdf
|
5 Dezember, 2020 um 16:33 Uhr
Wo kann ich dieses Gerät erwerben und was ist der Preis?
Bietet ihr auch Produktschulungen an?
7 Dezember, 2020 um 11:15 Uhr
Das Messgerät ist über den örtlichen Elektrogroßhandel erhältlich, bitte erfragen Sie auch dort den Preis. Schulungen werden von unserem Außendienst durchgeführt werden, sobald die Corona-Situation dies zulässt. Einladungen erfolgen durch den Großhandel. Auch eine individuelle Schulung können wir in Absprache anbieten.