BVE 8-02P 8-way splitter | 5…1218 MHz | housing design 02

  • High return loss

  • For multimedia-use

  • Inputs and outputs hum-suppressed

  • High intermodulation suppression

  • Class A (+10 dB) according to EN 50083-2

  • Return loss and isolation according to VFKD TS 220

  • Vodafone listed



Bild CE.png Bild KlasseA+10.png Bild VodafoneGelistet.png Bild UltraHD.png Bild AND.png Bild HFC.png

Type BVE 8-02P
Order no. BVE00802P
GTIN 7611682006230
PE 1
VE 1
EU custom tariff number 85291080
Frequency range 5…1218 MHz
Screening factor acc. to EN 50083-2 Class A + 10 dB
Intermodulation ratio (EN 60728-4) 120 dBµV
Splitting 8-way
Distribution
Distribution loss ≤ 10.2 ±1 dB @ 5 … 40 MHz
≤ 10.5 dB @ 40 … 470 MHz
≤ 11.5 dB @ 470 … 862 MHz
≤ 12.0 dB @ 862 … 1006 MHz
≤ 14.5 dB @ 1006 … 1300 MHz
RF connectors
Type F-Buchse (IEC 61169-24)
Isolation
Out-Out ≥ 27 dB @ 5 … 40 MHz
≥ 32 dB @ 40 … 470 MHz
≥ 30 dB @ 470 … 862 MHz
≥ 28 dB @ 862 … 1006 MHz
≥ 26 dB @ 1006 … 1300 MHz
Connectors
Connector type F
Return loss ≥ 20 dB @ 5 … 40 MHz
≥ 22 dB @ 40 … 470 MHz
≥ 20 dB @ 470 … 862 MHz
≥ 20 dB @ 862 … 1006 MHz
≥ 20 dB @ 1006 … 1300 MHz
General
Operating temperature range −15 °C … +60 °C
Dimensions (W × H × D) appr. 115 x 39 x 54 mm
Weight 0.220 kg
IP code IP67

Ask a question

Your email address will not be published. Required fields are marked *


  1. THIRIOT:

    Good evening team Axing,

    Which coaxial connectors must be used to connect the following products :
    BV3 3-01 with BVE 8-02P with QEW 8-50 or
    BV3 3-01 with BVE 6-02P with QEW 6-50 ?

    Normally the same. But please confirm.

    Kind regards and schoen week-end,

    Jean-Yves Thiriot

    • AXING:

      All devices are equipped with standard F-connectors.