Suitable for DOCSIS 3.1 and 4.0
-
Class A (+10 dB) according to EN 50083-2
-
Inputs and outputs hum-suppressed
-
High intermodulation suppression
-
High return loss and isolation
Type | BAB 1-12X |
---|---|
Order no. | BAB00112X |
GTIN | 7611682009255 |
PE | 1 |
VE | 1 |
EU custom tariff number | 85291080 |
Frequency range | 5 … 1800 MHz |
---|---|
Screening factor acc. to EN 50083-2 | Class A + 10 dB |
Surge Protection | 1 kV @ 1.2/50 μs surge voltage according to IEC 61000-4-5 / 160 Vdc impulse and UM TS 41 |
Intermodulation ratio (EN 60728-4) | < −115 dBc @ 120 dBµV |
Taps | 1-fach |
Tap loss |
12.0 ±0.5 dB @ 10 MHz 12.0 ±0.2 dB @ 65 MHz 11.9 ±0.2 dB @ 108 MHz 11.9 ±0.2 dB @ 204 MHz 11.9 ±0.2 dB @ 258 MHz 11.9 ±0.3 dB @ 470 MHz 11.9 ±0.3 dB @ 862 MHz 11.9 ±0.4 dB @ 1218 MHz 12.5 ±0.5 dB @ 1794 MHz |
Through loss |
0.9 ±0.2 dB @ 10 MHz 1.1 ±0.2 dB @ 65 MHz 0.9 ±0.2 dB @ 108 MHz 0.9 ±0.2 dB @ 204 MHz 0.9 ±0.2 dB @ 258 MHz 1.0 ±0.3 dB @ 470 MHz 1.2 ±0.3 dB @ 862 MHz 1.3 ±0.4 dB @ 1218 MHz 1.8 ±0.5 dB @ 1794 MHz |
RF connectors | |
Type | F-Buchse (IEC 61169-24) |
Isolation | |
Tap-Out |
> 28 dB @ 10 … 204 MHz > 30 dB @ 204 … 862 MHz > 28 dB @ 862 … 1218 MHz > 25 dB @ 1218 … 1794 MHz |
Connectors | |
Connector type | F female (IEC 61169-24) |
Impedance | 75 Ohm |
Return loss |
> 19 dB @ 10 … 204 MHz > 20 dB @ 204 … 862 MHz > 20 dB @ 862 … 1218 MHz > 21 dB @ 1218 … 1794 MHz |
General | |
Operating temperature range | −15 °C … +60 °C |
Dimensions (W × H × D) appr. | 45 × 55 × 25 mm |
IP code | IP67 |
Data sheet | Data sheet BAB 1-12X.pdf |
---|
Ask a question