Recommended replacement product: SES 5216-06
-
Suitable for checking, level control and troubleshooting
-
Analogue channels in the VHF range (f < 300 MHz) and digital channels in the UHF range (f > 300 MHz) can be measured
-
Including: Patch cable (F/F, 30 cm) and Adapter (IEC female/F-female)

Type | BZU 10-00 |
---|---|
Order no. | BZU01000 |
GTIN | 7611682001921 |
PE | 1 |
VE | 1 |
EU custom tariff number | 90303330 |
Frequency range |
188…230 MHz (CH 7...CH 12 ) 334...374 MHz (S 25...S 29 ) |
---|---|
Measurement range | 60...95 dBµV |
Impedance | 75 Ohm |
Connectors | |
RF-Input | F-female |
General | |
Operating voltage | 9 VDC (PP3) |
Power consumption | 450 mW |
Current consumption | 50 mA |
Dimensions (W × H × D) appr. | 60 x 120 x 26 mm |
Weight | 0.110 kg |
Data sheet | Data sheet BZU 10-00.pdf |
---|---|
Operational instructions |
BA_BZU-10-00.pdf
|
5 März, 2021 um 11:27 Uhr
Guten Tag, bei meinem BZU 10-00 leuchtet immer auch die rote “<55" LED, auch wenn z. B. die grüne LED gleichzeitig bei "75" leuchtet.
Wie kann ich das interpretieren, also z. B. Gleichzeitig "75" grün und "<55" rot?
Mit freundlichen Grüßen
Klaus Bär
5 März, 2021 um 17:01 Uhr
Hier scheint es sich leider um eine Fehlfunktion Ihres Gerätes zu handeln. Es sollte nicht passieren, dass diese beiden LEDs zugleich leuchten. Bitte reklamieren Sie den Tester bei dem Verkäufer.