{"id":49677,"date":"2026-03-13T16:47:01","date_gmt":"2026-03-13T15:47:01","guid":{"rendered":"https:\/\/axing.com\/how-to-feed-axing-headends-via-single-cable-systems\/"},"modified":"2026-04-08T08:31:56","modified_gmt":"2026-04-08T06:31:56","slug":"headends-via-singlecable","status":"publish","type":"post","link":"https:\/\/axing.com\/en\/headends-via-singlecable\/","title":{"rendered":"How to feed AXING Headends via Single-Cable Systems"},"content":{"rendered":"<h1>AXING Application Note<\/h1>\n<p>AXING headends support the reception of satellite signals via single-cable distribution systems (UNICABLE I and UNICABLE II (JESS) according to EN50494 \/ EN50607). This allows a headend to be supplied via a single coaxial cable.<br \/>\nThe use of single-cable technology significantly reduces cabling efforts. Depending on the installation, the headend can receive satellite signals in various ways:<\/p>\n<ul>\n<li>Direct connection to a <a href=\"https:\/\/axing.com\/en\/produkt\/sco00224-en\/\">single-cable LNB<\/a><\/li>\n<li>Connection via a <a href=\"https:\/\/axing.com\/en\/produkt\/ses521606n-en\/\">single-cable multiswitch<\/a><\/li>\n<li>Connection to a conventional satellite system with a quattro or quad LNB or <a href=\"https:\/\/axing.com\/en\/produkte\/multischalter\/2sat-positionen\/\">multiswitch<\/a><\/li>\n<\/ul>\n<p><a href=\"https:\/\/axing.com\/wp-content\/uploads\/2026\/03\/BSP_MK00812C_Singlecable.png\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-large wp-image-49708\" src=\"https:\/\/axing.com\/wp-content\/uploads\/2026\/03\/BSP_MK00812C_Singlecable-1024x810.png\" alt=\"\" width=\"1024\" height=\"810\" srcset=\"https:\/\/axing.com\/wp-content\/uploads\/2026\/03\/BSP_MK00812C_Singlecable-1024x810.png 1024w, https:\/\/axing.com\/wp-content\/uploads\/2026\/03\/BSP_MK00812C_Singlecable-300x237.png 300w, https:\/\/axing.com\/wp-content\/uploads\/2026\/03\/BSP_MK00812C_Singlecable-768x607.png 768w, https:\/\/axing.com\/wp-content\/uploads\/2026\/03\/BSP_MK00812C_Singlecable.png 1294w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/a><\/p>\n<p>All current AXING headends support single-cable reception. The new MK-C and MK-N headend series particularly benefit from this. They have four SAT inputs and a built\u2011in switching matrix. In combination with a single-cable system, the headend can be supplied with all available SAT transponders via a single coaxial cable. This enables flexible system planning and reduces installation effort.<\/p>\n<h2>Configuration of single-cable reception<\/h2>\n<p>The satellite reception parameters are configured in the <strong>INITIALISATION<\/strong> menu of the headend user interface. The settings for the single-cable system are made in PHASE 1 \u2013 Tuner Configuration. After entering the standard transponder parameters (e.g. frequency and polarisation), only a few additional settings are required. The figure below shows an example configuration.<\/p>\n<p><a href=\"https:\/\/axing.com\/wp-content\/uploads\/2026\/03\/Bild_2.png\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-49671\" src=\"https:\/\/axing.com\/wp-content\/uploads\/2026\/03\/Bild_2.png\" alt=\"\" width=\"1024\" height=\"362\" srcset=\"https:\/\/axing.com\/wp-content\/uploads\/2026\/03\/Bild_2.png 1024w, https:\/\/axing.com\/wp-content\/uploads\/2026\/03\/Bild_2-300x106.png 300w, https:\/\/axing.com\/wp-content\/uploads\/2026\/03\/Bild_2-768x272.png 768w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/a><\/p>\n<ul>\n<li>Select Unicable II as the reception mode<\/li>\n<li>Select SAT system<\/li>\n<li>Select Unicable User Band (UB)<\/li>\n<li>Enter UB frequency according to the frequency list of the used LNB or multiswitch<\/li>\n<li>Enter desired transponder parameters such as frequency and polarisation<\/li>\n<\/ul>\n<h3>Installation notes<\/h3>\n<ul>\n<li>Each SAT tuner must be assigned its own User Band (UB).<\/li>\n<li>The configured UB frequency must match exactly the LNB or multiswitch used.<\/li>\n<li>EN50607 (UNICABLE II) supports up to 32 User Bands<\/li>\n<\/ul>\n<h3>User Band frequency list<\/h3>\n<table>\n<tbody>\n<tr>\n<td width=\"85\"><strong>UB<\/strong><\/td>\n<td width=\"113\"><strong>UB Frequency<\/strong><\/td>\n<td width=\"189\"><strong>Used in LNB<\/strong><\/td>\n<td width=\"217\"><strong>Used in multiswitch<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"85\">UB 1<\/td>\n<td width=\"113\">975 MHz<\/td>\n<td width=\"189\">SCO 2-24<\/td>\n<td width=\"217\">SES 5216-06N<\/td>\n<\/tr>\n<tr>\n<td width=\"85\">UB 2<\/td>\n<td width=\"113\">1025 MHz<\/td>\n<td width=\"189\">SCO 2-24<\/td>\n<td width=\"217\">SES 5216-06N<\/td>\n<\/tr>\n<tr>\n<td width=\"85\">UB 3<\/td>\n<td width=\"113\">1075 MHz<\/td>\n<td width=\"189\">SCO 2-24<\/td>\n<td width=\"217\">SES 5216-06N<\/td>\n<\/tr>\n<tr>\n<td width=\"85\">UB 4<\/td>\n<td width=\"113\">1125 MHz<\/td>\n<td width=\"189\">SCO 2-24<\/td>\n<td width=\"217\">SES 5216-06N<\/td>\n<\/tr>\n<tr>\n<td width=\"85\">UB 5<\/td>\n<td width=\"113\">1175 MHz<\/td>\n<td width=\"189\">SCO 2-24<\/td>\n<td width=\"217\">SES 5216-06N<\/td>\n<\/tr>\n<tr>\n<td width=\"85\">UB 6<\/td>\n<td width=\"113\">1225 MHz<\/td>\n<td width=\"189\">SCO 2-24<\/td>\n<td width=\"217\">SES 5216-06N<\/td>\n<\/tr>\n<tr>\n<td width=\"85\">UB 7<\/td>\n<td width=\"113\">1275 MHz<\/td>\n<td width=\"189\">SCO 2-24<\/td>\n<td width=\"217\">SES 5216-06N<\/td>\n<\/tr>\n<tr>\n<td width=\"85\">UB 8<\/td>\n<td width=\"113\">1325 MHz<\/td>\n<td width=\"189\">SCO 2-24<\/td>\n<td width=\"217\">SES 5216-06N<\/td>\n<\/tr>\n<tr>\n<td width=\"85\">UB 9<\/td>\n<td width=\"113\">1375 MHz<\/td>\n<td width=\"189\">SCO 2-24<\/td>\n<td width=\"217\">SES 5216-06N<\/td>\n<\/tr>\n<tr>\n<td width=\"85\">UB 10<\/td>\n<td width=\"113\">1425 MHz<\/td>\n<td width=\"189\">SCO 2-24<\/td>\n<td width=\"217\">SES 5216-06N<\/td>\n<\/tr>\n<tr>\n<td width=\"85\">UB 11<\/td>\n<td width=\"113\">1475 MHz<\/td>\n<td width=\"189\">SCO 2-24<\/td>\n<td width=\"217\">SES 5216-06N<\/td>\n<\/tr>\n<tr>\n<td width=\"85\">UB 12<\/td>\n<td width=\"113\">1525 MHz<\/td>\n<td width=\"189\">SCO 2-24<\/td>\n<td width=\"217\">SES 5216-06N<\/td>\n<\/tr>\n<tr>\n<td width=\"85\">UB 13<\/td>\n<td width=\"113\">1575 MHz<\/td>\n<td width=\"189\">SCO 2-24<\/td>\n<td width=\"217\">SES 5216-06N<\/td>\n<\/tr>\n<tr>\n<td width=\"85\">UB 14<\/td>\n<td width=\"113\">1625 MHz<\/td>\n<td width=\"189\">SCO 2-24<\/td>\n<td width=\"217\">SES 5216-06N<\/td>\n<\/tr>\n<tr>\n<td width=\"85\">UB 15<\/td>\n<td width=\"113\">1675 MHz<\/td>\n<td width=\"189\">SCO 2-24<\/td>\n<td width=\"217\">SES 5216-06N<\/td>\n<\/tr>\n<tr>\n<td width=\"85\">UB 16<\/td>\n<td width=\"113\">1725 MHz<\/td>\n<td width=\"189\">SCO 2-24<\/td>\n<td width=\"217\">SES 5216-06N<\/td>\n<\/tr>\n<tr>\n<td width=\"85\">UB 17<\/td>\n<td width=\"113\">1775 MHz<\/td>\n<td width=\"189\">SCO 2-24<\/td>\n<td width=\"217\"><\/td>\n<\/tr>\n<tr>\n<td width=\"85\">UB 18<\/td>\n<td width=\"113\">1825 MHz<\/td>\n<td width=\"189\">SCO 2-24<\/td>\n<td width=\"217\"><\/td>\n<\/tr>\n<tr>\n<td width=\"85\">UB 19<\/td>\n<td width=\"113\">1875 MHz<\/td>\n<td width=\"189\">SCO 2-24<\/td>\n<td width=\"217\"><\/td>\n<\/tr>\n<tr>\n<td width=\"85\">UB 20<\/td>\n<td width=\"113\">1925 MHz<\/td>\n<td width=\"189\">SCO 2-24<\/td>\n<td width=\"217\"><\/td>\n<\/tr>\n<tr>\n<td width=\"85\">UB 21<\/td>\n<td width=\"113\">1975 MHz<\/td>\n<td width=\"189\">SCO 2-24<\/td>\n<td width=\"217\"><\/td>\n<\/tr>\n<tr>\n<td width=\"85\">UB 22<\/td>\n<td width=\"113\">2025 MHz<\/td>\n<td width=\"189\">SCO 2-24<\/td>\n<td width=\"217\"><\/td>\n<\/tr>\n<tr>\n<td width=\"85\">UB 23<\/td>\n<td width=\"113\">2075 MHz<\/td>\n<td width=\"189\">SCO 2-24<\/td>\n<td width=\"217\"><\/td>\n<\/tr>\n<tr>\n<td width=\"85\">UB 24<\/td>\n<td width=\"113\">2125 MHz<\/td>\n<td width=\"189\">SCO 2-24<\/td>\n<td width=\"217\"><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><a href=\"http:\/\/axing.com\/pdf-generator\/49677\">Article as PDF<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>AXING headends support the reception of satellite signals via single-cable distribution systems (UNICABLE I and UNICABLE II (JESS) in accordance with EN50494 \/ EN50607). This allows a headend to be supplied via a single coaxial cable.<br \/>\nThe use of single-cable technology significantly reduces the amount of cabling required.<\/p>\n","protected":false},"author":1,"featured_media":49682,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[3329,3331,3330],"tags":[],"class_list":["post-49677","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-application-notes","category-configuration","category-headends-en"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v26.2 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>How to feed AXING Headends via Single-Cable Systems - AXING AG<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/axing.com\/en\/headends-via-singlecable\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"How to feed AXING Headends via Single-Cable Systems - AXING AG\" \/>\n<meta property=\"og:description\" content=\"AXING headends support the reception of satellite signals via single-cable distribution systems (UNICABLE I and UNICABLE II (JESS) in accordance with EN50494 \/ EN50607). This allows a headend to be supplied via a single coaxial cable. The use of single-cable technology significantly reduces the amount of cabling required.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/axing.com\/en\/headends-via-singlecable\/\" \/>\n<meta property=\"og:site_name\" content=\"AXING AG\" \/>\n<meta property=\"article:published_time\" content=\"2026-03-13T15:47:01+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-04-08T06:31:56+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/axing.com\/wp-content\/uploads\/2026\/03\/AP_Note_MK-C_Unicable-e1773844318516.png\" \/>\n\t<meta property=\"og:image:width\" content=\"250\" \/>\n\t<meta property=\"og:image:height\" content=\"56\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"AXING\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"AXING\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/axing.com\/en\/headends-via-singlecable\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/axing.com\/en\/headends-via-singlecable\/\"},\"author\":{\"name\":\"AXING\",\"@id\":\"https:\/\/axing.com\/#\/schema\/person\/957baed8bac11ae8753e53d6273e518d\"},\"headline\":\"How to feed AXING Headends via Single-Cable Systems\",\"datePublished\":\"2026-03-13T15:47:01+00:00\",\"dateModified\":\"2026-04-08T06:31:56+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/axing.com\/en\/headends-via-singlecable\/\"},\"wordCount\":438,\"publisher\":{\"@id\":\"https:\/\/axing.com\/#organization\"},\"image\":{\"@id\":\"https:\/\/axing.com\/en\/headends-via-singlecable\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/axing.com\/wp-content\/uploads\/2026\/03\/AP_Note_MK-C_Unicable-e1773844318516.png\",\"articleSection\":[\"Application Notes\",\"Configuration\",\"Headends\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/axing.com\/en\/headends-via-singlecable\/\",\"url\":\"https:\/\/axing.com\/en\/headends-via-singlecable\/\",\"name\":\"How to feed AXING Headends via Single-Cable Systems - AXING AG\",\"isPartOf\":{\"@id\":\"https:\/\/axing.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/axing.com\/en\/headends-via-singlecable\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/axing.com\/en\/headends-via-singlecable\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/axing.com\/wp-content\/uploads\/2026\/03\/AP_Note_MK-C_Unicable-e1773844318516.png\",\"datePublished\":\"2026-03-13T15:47:01+00:00\",\"dateModified\":\"2026-04-08T06:31:56+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/axing.com\/en\/headends-via-singlecable\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/axing.com\/en\/headends-via-singlecable\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/axing.com\/en\/headends-via-singlecable\/#primaryimage\",\"url\":\"https:\/\/axing.com\/wp-content\/uploads\/2026\/03\/AP_Note_MK-C_Unicable-e1773844318516.png\",\"contentUrl\":\"https:\/\/axing.com\/wp-content\/uploads\/2026\/03\/AP_Note_MK-C_Unicable-e1773844318516.png\",\"width\":250,\"height\":56},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/axing.com\/en\/headends-via-singlecable\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Startseite\",\"item\":\"https:\/\/axing.com\/en\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"How to feed AXING Headends via Single-Cable Systems\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/axing.com\/#website\",\"url\":\"https:\/\/axing.com\/\",\"name\":\"AXING AG\",\"description\":\"Partnerschaft | Innovation | Qualit\u00e4t\",\"publisher\":{\"@id\":\"https:\/\/axing.com\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/axing.com\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/axing.com\/#organization\",\"name\":\"AXING AG\",\"url\":\"https:\/\/axing.com\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/axing.com\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/axing.com\/wp-content\/uploads\/2016\/01\/Logo_HiDPI.png\",\"contentUrl\":\"https:\/\/axing.com\/wp-content\/uploads\/2016\/01\/Logo_HiDPI.png\",\"width\":604,\"height\":100,\"caption\":\"AXING AG\"},\"image\":{\"@id\":\"https:\/\/axing.com\/#\/schema\/logo\/image\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\/\/axing.com\/#\/schema\/person\/957baed8bac11ae8753e53d6273e518d\",\"name\":\"AXING\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/axing.com\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/4a59ec3a4e9e02d09463aa60a042b56f81a19ffc9651f4e9d1fc66cff8722163?s=96&d=blank&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/4a59ec3a4e9e02d09463aa60a042b56f81a19ffc9651f4e9d1fc66cff8722163?s=96&d=blank&r=g\",\"caption\":\"AXING\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"How to feed AXING Headends via Single-Cable Systems - AXING AG","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/axing.com\/en\/headends-via-singlecable\/","og_locale":"en_US","og_type":"article","og_title":"How to feed AXING Headends via Single-Cable Systems - AXING AG","og_description":"AXING headends support the reception of satellite signals via single-cable distribution systems (UNICABLE I and UNICABLE II (JESS) in accordance with EN50494 \/ EN50607). This allows a headend to be supplied via a single coaxial cable. The use of single-cable technology significantly reduces the amount of cabling required.","og_url":"https:\/\/axing.com\/en\/headends-via-singlecable\/","og_site_name":"AXING AG","article_published_time":"2026-03-13T15:47:01+00:00","article_modified_time":"2026-04-08T06:31:56+00:00","og_image":[{"width":250,"height":56,"url":"https:\/\/axing.com\/wp-content\/uploads\/2026\/03\/AP_Note_MK-C_Unicable-e1773844318516.png","type":"image\/png"}],"author":"AXING","twitter_card":"summary_large_image","twitter_misc":{"Written by":"AXING","Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/axing.com\/en\/headends-via-singlecable\/#article","isPartOf":{"@id":"https:\/\/axing.com\/en\/headends-via-singlecable\/"},"author":{"name":"AXING","@id":"https:\/\/axing.com\/#\/schema\/person\/957baed8bac11ae8753e53d6273e518d"},"headline":"How to feed AXING Headends via Single-Cable Systems","datePublished":"2026-03-13T15:47:01+00:00","dateModified":"2026-04-08T06:31:56+00:00","mainEntityOfPage":{"@id":"https:\/\/axing.com\/en\/headends-via-singlecable\/"},"wordCount":438,"publisher":{"@id":"https:\/\/axing.com\/#organization"},"image":{"@id":"https:\/\/axing.com\/en\/headends-via-singlecable\/#primaryimage"},"thumbnailUrl":"https:\/\/axing.com\/wp-content\/uploads\/2026\/03\/AP_Note_MK-C_Unicable-e1773844318516.png","articleSection":["Application Notes","Configuration","Headends"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/axing.com\/en\/headends-via-singlecable\/","url":"https:\/\/axing.com\/en\/headends-via-singlecable\/","name":"How to feed AXING Headends via Single-Cable Systems - AXING AG","isPartOf":{"@id":"https:\/\/axing.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/axing.com\/en\/headends-via-singlecable\/#primaryimage"},"image":{"@id":"https:\/\/axing.com\/en\/headends-via-singlecable\/#primaryimage"},"thumbnailUrl":"https:\/\/axing.com\/wp-content\/uploads\/2026\/03\/AP_Note_MK-C_Unicable-e1773844318516.png","datePublished":"2026-03-13T15:47:01+00:00","dateModified":"2026-04-08T06:31:56+00:00","breadcrumb":{"@id":"https:\/\/axing.com\/en\/headends-via-singlecable\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/axing.com\/en\/headends-via-singlecable\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/axing.com\/en\/headends-via-singlecable\/#primaryimage","url":"https:\/\/axing.com\/wp-content\/uploads\/2026\/03\/AP_Note_MK-C_Unicable-e1773844318516.png","contentUrl":"https:\/\/axing.com\/wp-content\/uploads\/2026\/03\/AP_Note_MK-C_Unicable-e1773844318516.png","width":250,"height":56},{"@type":"BreadcrumbList","@id":"https:\/\/axing.com\/en\/headends-via-singlecable\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Startseite","item":"https:\/\/axing.com\/en\/"},{"@type":"ListItem","position":2,"name":"How to feed AXING Headends via Single-Cable Systems"}]},{"@type":"WebSite","@id":"https:\/\/axing.com\/#website","url":"https:\/\/axing.com\/","name":"AXING AG","description":"Partnerschaft | Innovation | Qualit\u00e4t","publisher":{"@id":"https:\/\/axing.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/axing.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/axing.com\/#organization","name":"AXING AG","url":"https:\/\/axing.com\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/axing.com\/#\/schema\/logo\/image\/","url":"https:\/\/axing.com\/wp-content\/uploads\/2016\/01\/Logo_HiDPI.png","contentUrl":"https:\/\/axing.com\/wp-content\/uploads\/2016\/01\/Logo_HiDPI.png","width":604,"height":100,"caption":"AXING AG"},"image":{"@id":"https:\/\/axing.com\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/axing.com\/#\/schema\/person\/957baed8bac11ae8753e53d6273e518d","name":"AXING","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/axing.com\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/4a59ec3a4e9e02d09463aa60a042b56f81a19ffc9651f4e9d1fc66cff8722163?s=96&d=blank&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/4a59ec3a4e9e02d09463aa60a042b56f81a19ffc9651f4e9d1fc66cff8722163?s=96&d=blank&r=g","caption":"AXING"}}]}},"_links":{"self":[{"href":"https:\/\/axing.com\/en\/wp-json\/wp\/v2\/posts\/49677","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/axing.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/axing.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/axing.com\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/axing.com\/en\/wp-json\/wp\/v2\/comments?post=49677"}],"version-history":[{"count":6,"href":"https:\/\/axing.com\/en\/wp-json\/wp\/v2\/posts\/49677\/revisions"}],"predecessor-version":[{"id":49773,"href":"https:\/\/axing.com\/en\/wp-json\/wp\/v2\/posts\/49677\/revisions\/49773"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/axing.com\/en\/wp-json\/wp\/v2\/media\/49682"}],"wp:attachment":[{"href":"https:\/\/axing.com\/en\/wp-json\/wp\/v2\/media?parent=49677"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/axing.com\/en\/wp-json\/wp\/v2\/categories?post=49677"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/axing.com\/en\/wp-json\/wp\/v2\/tags?post=49677"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}