{"id":31743,"date":"2018-05-11T12:20:31","date_gmt":"2018-05-11T12:20:31","guid":{"rendered":"https:\/\/axing.com\/edit-nit-and-switch-off-individual-pids-at-headends\/"},"modified":"2021-04-02T18:54:00","modified_gmt":"2021-04-02T16:54:00","slug":"edit-nit-and-switch-off-individual-pids-at-headends","status":"publish","type":"post","link":"https:\/\/axing.com\/en\/edit-nit-and-switch-off-individual-pids-at-headends\/","title":{"rendered":"Edit NIT and switch off individual PIDs of headends"},"content":{"rendered":"<p>11 May 2018 | We offer two extensions for individual adjustment of our new headend generation (series MK XX-0X and SKM XX-oX): The MKS 1-00 extension generates a NIT table, the MKS 1-01 enables PID filtering. The AXING Support will install both extensions on customer request. Both software functionalities are explained in detail below:<\/p>\n<h3>NIT &#8211; Network Information Table<\/h3>\n<p>With the software extension MKS 1-00, a NIT (Network Information Table) can be read out of the devices, edited and uploaded back into the devices. The NIT Network Information Table transmits a series of parameters in the digital data stream that are necessary for a scan of the receivers. The specific parameters within the NIT, such as ONID &#8211; Original Network ID and TS-ID &#8211; Transmitting Subscriber ID, can each be configured. In addition, transmission parameters can be added and changed manually from other AXING headends as well as from headends of other manufacturers. This makes it easy to manage the receivers&#8217;s channels at the headend. The channel searching procedure will be\u00a0 faster and more reliable.<\/p>\n<div id=\"attachment_31623\" style=\"width: 692px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/axing.com\/wp-content\/uploads\/2018\/04\/menu-nit.png\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-31623\" class=\"size-full wp-image-31623\" src=\"https:\/\/axing.com\/wp-content\/uploads\/2018\/04\/menu-nit.png\" alt=\"NIT-Editierung\" width=\"682\" height=\"440\" srcset=\"https:\/\/axing.com\/wp-content\/uploads\/2018\/04\/menu-nit.png 682w, https:\/\/axing.com\/wp-content\/uploads\/2018\/04\/menu-nit-300x194.png 300w\" sizes=\"auto, (max-width: 682px) 100vw, 682px\" \/><\/a><p id=\"caption-attachment-31623\" class=\"wp-caption-text\">NIT editing<\/p><\/div>\n<h3>NIT editing<\/h3>\n<p>The LCN (Logical channel numbering) is also located within the NIT, which enables virtual channel list assignment for TV\/radio programmes. Receivers which support LCN sort the program automatically after running a search process. With the MKS 1-00, synchronization is also possible if several headends are used. Within the cable network, the user always finds a program on the same program position.PID &#8211; Packet Identifier<\/p>\n<p>Each digital data stream (transport stream) is composed of several elementary streams, each elementary stream having its own identifier, the so-called PID. An elementary stream can be a video, audio or data stream. Some transport streams contain several audio languages (audio PIDs), for example.<\/p>\n<div id=\"attachment_31621\" style=\"width: 877px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/axing.com\/wp-content\/uploads\/2018\/04\/menu-pid-sd.png\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-31621\" class=\"size-full wp-image-31621\" src=\"https:\/\/axing.com\/wp-content\/uploads\/2018\/04\/menu-pid-sd.png\" alt=\"PID Editierung\" width=\"867\" height=\"449\" srcset=\"https:\/\/axing.com\/wp-content\/uploads\/2018\/04\/menu-pid-sd.png 867w, https:\/\/axing.com\/wp-content\/uploads\/2018\/04\/menu-pid-sd-300x155.png 300w, https:\/\/axing.com\/wp-content\/uploads\/2018\/04\/menu-pid-sd-768x398.png 768w\" sizes=\"auto, (max-width: 867px) 100vw, 867px\" \/><\/a><p id=\"caption-attachment-31621\" class=\"wp-caption-text\">PID filter<\/p><\/div>\n<h3>PID filtering<\/h3>\n<p>If not all channel data streams are required due to the application, PID filtering is possible with the software extension MKS 1-01. All existing PIDs of a transport stream are listed, which can then be selected individually. For example, you can suppress audio PIDs with foreign language sound channels or AC-3 surround sound. Teletext can be excluded for use in a correctional facility. If PIDs are deselected, the transport stream is marked as modified and this particular stream element is no longer transmitted. This reduces the overall data rate of a transport stream, resulting in a lower bandwidth. This can become\u00a0 important for conversion from DVB-S to DVB-T, since a DVB-T channel has a lower data capacity. Data rate can be &#8220;saved&#8221; by filtering. Furthermore, the SIDs (Service ID) can be reassigned via this function with the software extension MKS 1-01.<\/p>\n<h3>Advantages:<\/h3>\n\t \n\t \n\t\t\n\t\t<ul class=\"with_icons default default_size\" data-rt-animation-group=\"group\">\n\t\t\n <li class=\"box one first last\" data-rt-animate=\"animate\" data-rt-animation-type=\"fadeInDown\"><span class=\"icon-ok icon\"><\/span> <p>Generate a common NIT, speed up and simplify the program search of the receivers<\/p><\/li>\n <li class=\"box one first last\" data-rt-animate=\"animate\" data-rt-animation-type=\"fadeInDown\"><span class=\"icon-ok icon\"><\/span> <p>Allows a channel list assignment via LCN for all receivers using multiple headends<\/p><\/li>\n <li class=\"box one first last\" data-rt-animate=\"animate\" data-rt-animation-type=\"fadeInDown\"><span class=\"icon-ok icon\"><\/span> <p>PID filtering meets operator requirements (e.g. exclusion of teletext)<\/p><\/li>\n <li class=\"box one first last\" data-rt-animate=\"animate\" data-rt-animation-type=\"fadeInDown\"><span class=\"icon-ok icon\"><\/span> <p>Offers full control over the services in the cable network<\/p><\/li>\n\n\t\t<\/ul>\n\t\n","protected":false},"excerpt":{"rendered":"<p>11 May 2018 | We offer two extensions for individual adjustment of our new headend generation (series MK XX-0X and SKM XX-oX): The MKS 1-00 extension generates a NIT table, the MKS 1-01 enables PID filtering. The AXING Support will install both extensions on customer request. Both software functionalities are explained in detail below: NIT [&hellip;]<\/p>\n","protected":false},"author":7,"featured_media":33493,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[3147],"tags":[3148],"class_list":["post-31743","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-solutions-en","tag-headend"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v26.2 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Edit NIT and switch off individual PIDs of headends - AXING AG<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/axing.com\/en\/edit-nit-and-switch-off-individual-pids-at-headends\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Edit NIT and switch off individual PIDs of headends - AXING AG\" \/>\n<meta property=\"og:description\" content=\"11 May 2018 | We offer two extensions for individual adjustment of our new headend generation (series MK XX-0X and SKM XX-oX): The MKS 1-00 extension generates a NIT table, the MKS 1-01 enables PID filtering. The AXING Support will install both extensions on customer request. Both software functionalities are explained in detail below: NIT [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/axing.com\/en\/edit-nit-and-switch-off-individual-pids-at-headends\/\" \/>\n<meta property=\"og:site_name\" content=\"AXING AG\" \/>\n<meta property=\"article:published_time\" content=\"2018-05-11T12:20:31+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2021-04-02T16:54:00+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/axing.com\/wp-content\/uploads\/2018\/04\/PIC_MKS00100.png\" \/>\n\t<meta property=\"og:image:width\" content=\"500\" \/>\n\t<meta property=\"og:image:height\" content=\"300\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"AXING\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@axing_ag\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"AXING\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/axing.com\/en\/edit-nit-and-switch-off-individual-pids-at-headends\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/axing.com\/en\/edit-nit-and-switch-off-individual-pids-at-headends\/\"},\"author\":{\"name\":\"AXING\",\"@id\":\"https:\/\/axing.com\/#\/schema\/person\/2e57a1b68dd0501a2aaf26a8b9d78716\"},\"headline\":\"Edit NIT and switch off individual PIDs of headends\",\"datePublished\":\"2018-05-11T12:20:31+00:00\",\"dateModified\":\"2021-04-02T16:54:00+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/axing.com\/en\/edit-nit-and-switch-off-individual-pids-at-headends\/\"},\"wordCount\":549,\"publisher\":{\"@id\":\"https:\/\/axing.com\/#organization\"},\"image\":{\"@id\":\"https:\/\/axing.com\/en\/edit-nit-and-switch-off-individual-pids-at-headends\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/axing.com\/wp-content\/uploads\/2018\/04\/PIC_MKS00100.png\",\"keywords\":[\"headend\"],\"articleSection\":[\"Solutions\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/axing.com\/en\/edit-nit-and-switch-off-individual-pids-at-headends\/\",\"url\":\"https:\/\/axing.com\/en\/edit-nit-and-switch-off-individual-pids-at-headends\/\",\"name\":\"Edit NIT and switch off individual PIDs of headends - AXING AG\",\"isPartOf\":{\"@id\":\"https:\/\/axing.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/axing.com\/en\/edit-nit-and-switch-off-individual-pids-at-headends\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/axing.com\/en\/edit-nit-and-switch-off-individual-pids-at-headends\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/axing.com\/wp-content\/uploads\/2018\/04\/PIC_MKS00100.png\",\"datePublished\":\"2018-05-11T12:20:31+00:00\",\"dateModified\":\"2021-04-02T16:54:00+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/axing.com\/en\/edit-nit-and-switch-off-individual-pids-at-headends\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/axing.com\/en\/edit-nit-and-switch-off-individual-pids-at-headends\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/axing.com\/en\/edit-nit-and-switch-off-individual-pids-at-headends\/#primaryimage\",\"url\":\"https:\/\/axing.com\/wp-content\/uploads\/2018\/04\/PIC_MKS00100.png\",\"contentUrl\":\"https:\/\/axing.com\/wp-content\/uploads\/2018\/04\/PIC_MKS00100.png\",\"width\":500,\"height\":300},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/axing.com\/en\/edit-nit-and-switch-off-individual-pids-at-headends\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Startseite\",\"item\":\"https:\/\/axing.com\/en\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Edit NIT and switch off individual PIDs of headends\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/axing.com\/#website\",\"url\":\"https:\/\/axing.com\/\",\"name\":\"AXING AG\",\"description\":\"Partnerschaft | Innovation | Qualit\u00e4t\",\"publisher\":{\"@id\":\"https:\/\/axing.com\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/axing.com\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/axing.com\/#organization\",\"name\":\"AXING AG\",\"url\":\"https:\/\/axing.com\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/axing.com\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/axing.com\/wp-content\/uploads\/2016\/01\/Logo_HiDPI.png\",\"contentUrl\":\"https:\/\/axing.com\/wp-content\/uploads\/2016\/01\/Logo_HiDPI.png\",\"width\":604,\"height\":100,\"caption\":\"AXING AG\"},\"image\":{\"@id\":\"https:\/\/axing.com\/#\/schema\/logo\/image\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\/\/axing.com\/#\/schema\/person\/2e57a1b68dd0501a2aaf26a8b9d78716\",\"name\":\"AXING\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/axing.com\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/74ad8145b15fb62439544b8bdb0741a8680983b281d8f3eda89183eccebfd17f?s=96&d=blank&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/74ad8145b15fb62439544b8bdb0741a8680983b281d8f3eda89183eccebfd17f?s=96&d=blank&r=g\",\"caption\":\"AXING\"},\"sameAs\":[\"https:\/\/x.com\/axing_ag\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Edit NIT and switch off individual PIDs of headends - AXING AG","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/axing.com\/en\/edit-nit-and-switch-off-individual-pids-at-headends\/","og_locale":"en_US","og_type":"article","og_title":"Edit NIT and switch off individual PIDs of headends - AXING AG","og_description":"11 May 2018 | We offer two extensions for individual adjustment of our new headend generation (series MK XX-0X and SKM XX-oX): The MKS 1-00 extension generates a NIT table, the MKS 1-01 enables PID filtering. The AXING Support will install both extensions on customer request. Both software functionalities are explained in detail below: NIT [&hellip;]","og_url":"https:\/\/axing.com\/en\/edit-nit-and-switch-off-individual-pids-at-headends\/","og_site_name":"AXING AG","article_published_time":"2018-05-11T12:20:31+00:00","article_modified_time":"2021-04-02T16:54:00+00:00","og_image":[{"width":500,"height":300,"url":"https:\/\/axing.com\/wp-content\/uploads\/2018\/04\/PIC_MKS00100.png","type":"image\/png"}],"author":"AXING","twitter_card":"summary_large_image","twitter_creator":"@axing_ag","twitter_misc":{"Written by":"AXING","Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/axing.com\/en\/edit-nit-and-switch-off-individual-pids-at-headends\/#article","isPartOf":{"@id":"https:\/\/axing.com\/en\/edit-nit-and-switch-off-individual-pids-at-headends\/"},"author":{"name":"AXING","@id":"https:\/\/axing.com\/#\/schema\/person\/2e57a1b68dd0501a2aaf26a8b9d78716"},"headline":"Edit NIT and switch off individual PIDs of headends","datePublished":"2018-05-11T12:20:31+00:00","dateModified":"2021-04-02T16:54:00+00:00","mainEntityOfPage":{"@id":"https:\/\/axing.com\/en\/edit-nit-and-switch-off-individual-pids-at-headends\/"},"wordCount":549,"publisher":{"@id":"https:\/\/axing.com\/#organization"},"image":{"@id":"https:\/\/axing.com\/en\/edit-nit-and-switch-off-individual-pids-at-headends\/#primaryimage"},"thumbnailUrl":"https:\/\/axing.com\/wp-content\/uploads\/2018\/04\/PIC_MKS00100.png","keywords":["headend"],"articleSection":["Solutions"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/axing.com\/en\/edit-nit-and-switch-off-individual-pids-at-headends\/","url":"https:\/\/axing.com\/en\/edit-nit-and-switch-off-individual-pids-at-headends\/","name":"Edit NIT and switch off individual PIDs of headends - AXING AG","isPartOf":{"@id":"https:\/\/axing.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/axing.com\/en\/edit-nit-and-switch-off-individual-pids-at-headends\/#primaryimage"},"image":{"@id":"https:\/\/axing.com\/en\/edit-nit-and-switch-off-individual-pids-at-headends\/#primaryimage"},"thumbnailUrl":"https:\/\/axing.com\/wp-content\/uploads\/2018\/04\/PIC_MKS00100.png","datePublished":"2018-05-11T12:20:31+00:00","dateModified":"2021-04-02T16:54:00+00:00","breadcrumb":{"@id":"https:\/\/axing.com\/en\/edit-nit-and-switch-off-individual-pids-at-headends\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/axing.com\/en\/edit-nit-and-switch-off-individual-pids-at-headends\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/axing.com\/en\/edit-nit-and-switch-off-individual-pids-at-headends\/#primaryimage","url":"https:\/\/axing.com\/wp-content\/uploads\/2018\/04\/PIC_MKS00100.png","contentUrl":"https:\/\/axing.com\/wp-content\/uploads\/2018\/04\/PIC_MKS00100.png","width":500,"height":300},{"@type":"BreadcrumbList","@id":"https:\/\/axing.com\/en\/edit-nit-and-switch-off-individual-pids-at-headends\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Startseite","item":"https:\/\/axing.com\/en\/"},{"@type":"ListItem","position":2,"name":"Edit NIT and switch off individual PIDs of headends"}]},{"@type":"WebSite","@id":"https:\/\/axing.com\/#website","url":"https:\/\/axing.com\/","name":"AXING AG","description":"Partnerschaft | Innovation | Qualit\u00e4t","publisher":{"@id":"https:\/\/axing.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/axing.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/axing.com\/#organization","name":"AXING AG","url":"https:\/\/axing.com\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/axing.com\/#\/schema\/logo\/image\/","url":"https:\/\/axing.com\/wp-content\/uploads\/2016\/01\/Logo_HiDPI.png","contentUrl":"https:\/\/axing.com\/wp-content\/uploads\/2016\/01\/Logo_HiDPI.png","width":604,"height":100,"caption":"AXING AG"},"image":{"@id":"https:\/\/axing.com\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/axing.com\/#\/schema\/person\/2e57a1b68dd0501a2aaf26a8b9d78716","name":"AXING","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/axing.com\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/74ad8145b15fb62439544b8bdb0741a8680983b281d8f3eda89183eccebfd17f?s=96&d=blank&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/74ad8145b15fb62439544b8bdb0741a8680983b281d8f3eda89183eccebfd17f?s=96&d=blank&r=g","caption":"AXING"},"sameAs":["https:\/\/x.com\/axing_ag"]}]}},"_links":{"self":[{"href":"https:\/\/axing.com\/en\/wp-json\/wp\/v2\/posts\/31743","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/axing.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/axing.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/axing.com\/en\/wp-json\/wp\/v2\/users\/7"}],"replies":[{"embeddable":true,"href":"https:\/\/axing.com\/en\/wp-json\/wp\/v2\/comments?post=31743"}],"version-history":[{"count":4,"href":"https:\/\/axing.com\/en\/wp-json\/wp\/v2\/posts\/31743\/revisions"}],"predecessor-version":[{"id":41462,"href":"https:\/\/axing.com\/en\/wp-json\/wp\/v2\/posts\/31743\/revisions\/41462"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/axing.com\/en\/wp-json\/wp\/v2\/media\/33493"}],"wp:attachment":[{"href":"https:\/\/axing.com\/en\/wp-json\/wp\/v2\/media?parent=31743"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/axing.com\/en\/wp-json\/wp\/v2\/categories?post=31743"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/axing.com\/en\/wp-json\/wp\/v2\/tags?post=31743"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}